| General specifications |
| Switching element function |
NAMUR, NC |
| Rated operating distance |
1.5 mm |
| Installation |
embeddable |
| Output polarity |
DC |
| Assured operating distance |
0 ... 1.22 mm |
| Reduction factor rAl |
0.4 |
| Reduction factor rCu |
0.3 |
| Reduction factor r303 |
0.85 |
| Nominal ratings |
| Nominal voltage |
8 V |
| Switching frequency |
0 ... 400 Hz |
| Hysteresis |
typ. % |
| Current consumption |
|
| |
Measuring plate not detected |
min. 3 mA |
| |
Measuring plate detected |
≤ 1 mA |
| Limit data |
| Operating pressure dynamically |
350 bar (507.6 psi) |
| Compliance with standards and directives |
| Standard conformity |
|
| |
NAMUR |
EN 60947-5-6:2000
IEC 60947-5-6:1999 |
| Ambient conditions |
| Ambient temperature |
-25 ... 85 °C (-13 ... 185 °F) |
| Mechanical specifications |
| Core cross-section |
0.34 mm2 |
| Housing material |
Stainless steel |
| Sensing face |
Ceramic |
| Protection degree |
IP66 / IP68 |
| General information |
| Use in the hazardous area |
see instruction manuals |
| |
Category |
2G; 1D |