6ES7288-2DR08-0AA0
| 6ES72882DR080AA0 | S7-200 SMART,EM DR08,數字量輸出模塊,8 x 繼電器輸出 |
The TM150 Terminal Module is a DRIVE-CLiQ component for temperature evaluation. The temperature is measured in a temperature range from -99 °C to +250 °C for the following temperature sensors:
For the temperature sensor inputs, for each terminal block the evaluation can be parameterized for 1×2-wire, 2×2-wire, 3-wire or 4-wire. There is no electrical isolation in the TM150.
The temperature channels of a TM150 can be subdivided into 3 groups and evaluated together.
The following are located on the TM150 Terminal Module:
The status of the TM150 Terminal Module is indicated via a multi-color LED.
The TM150 Terminal Module is designed to be snapped onto a TH35 mounting rail in accordance with EN 60715.
Connection example of a TM150 Terminal Module
|
TM150 Terminal Module 6SL3055-0AA00-3LA0 |
|
|---|---|
|
Current consumption, max. at 24 V DC |
0.5 A |
|
2.5 mm2 |
|
20 A |
|
Temperature sensor inputs The inputs can be parameterized individually for the evaluation of sensors |
|
|
1.5 mm2 |
|
0.8 mA |
|
PE connection |
M4 screw |
|
Dimensions |
|
|
30 mm |
|
150 mm |
|
119 mm |
|
Weight, approx. |
|
變頻器必須始終通過換相電感連接線路供電。必須具有至少 4% 的uK!換相電感可以采用換流變壓器的形式或者對于適當的線路供電采用換相電抗器的形式。
可以認為線路供電是“剛性的”,功率系數 Ps/Sk ≤ 0.01 時。即使對于剛性供電,換相電感也必須具有至少 4% 的 uK 。
對于高速率轉換,線路電抗即有線路故障的限故障等級(短路功率)必須考慮進來;這也會導致更高的uK。對于視在驅動器功率的線路供電故障等級比例(短路功率)的推薦值為 > 33:1。
換相電抗器的規格根據勵磁電路或電樞中的額定電機電流確定。
運行在工頻 50 和 60Hz 下
電抗器的額定電流 ILn 在下表中進行了規定,適用于線路頻率 f = 50 Hz 時。電抗器可能運行在工頻 f = 60 Hz 的情況下。在這種情況下,應使用額定值高出 10% 的電抗器。
同時,電壓降 ΔV 增長 8%。
電抗器和無線干擾濾波器的布置
(1) 勵磁電路中的換相電感根據額定電機勵磁電流確定規格。
(2) 電樞電路中的換相電抗器根據額定電機電樞電流確定規格。
線路電流是直流電流的 0.82 倍。
(3) 用于電樞電路中的無線干擾抑制濾波器根據額定電機電樞電流確定規格。
線路電流是直流電流的 0.82 倍。
(4) 用于勵磁電路的無線干擾抑制濾波器根據額定電機勵磁電流確定規格。
(5) 電子裝置電源本身不需要無線干擾抑制濾波器。
電流消耗在 400 V 時為 1A,230V 時為 2A。
(6) 如果電樞電路、勵磁電路和電子裝置電源的電源電壓相同,則用于勵磁和電子裝置電源的電壓可以從用于電樞電路的無線干擾濾波器后面提取。