Simpson228測試儀對于與危險的泄漏電流,設計符合最新的UL、IEC和ANSI規格。228查出當前AC和DC漏出并且模仿人的反應在三個不同水平-- 反應,放棄,以及燒傷危險。每個Simpson228具有彈簧夾、指南和電池以及測試筆。查出危險AC & DC 泄漏電流在電子或電子設備導電性表面設計遇見新的IEC、ANSI和UL指南反應,放棄和無重負的燒傷危險網絡測量電池操作為最大輕便。
Opecifications
GENERAL
|
Reaction ResponseNetwork |
Let-Go ResponseNetwork |
UnweightedBurnHazard Response Network |
|
Equivalent network component values: |
Complies with values specified in IEC 990 (excluding fuse) |
|||
Equivalent measuring instrument load: |
1 MΩ- 10pF |
1 MΩ- 62 pF |
1 MΩ- 1 pF |
|
Ranges: |
0.3, 1, 3, 10 M.I.U. |
0.3, 1, 3, 10 M.I.U. |
0-100 mA RMS |
|
Current accuracy: |
±2% F.S. @ 60 Hz |
|||
Meter measurement method: |
True RMS |
|||
Meter frequency response: |
(Relative to ANSI C101-1992 or UL-1459 2nd edition) |
|||
DC to 1 Hz |
Pointer shall track within 5% of peak |
|||
2Hz to 19Hz (Accuracy not supported) |
|
|||
20 Hz to 200 KHz |
±2% F.S. |
±2.5% of F.S. |
±2% F.S. |
|
200 KHz to 1 MHz |
±2% F.S. |
±2.5% F.S. |
±5% F.S. |
|
Output sensitivity: |
Full scale meter indication equals 1V RMS (Measured with a 1 MΩ- 12 pF load) |
|||
Output accuracy: |
±2% of reading @ 60 Hz |
|||
Output frequency response: |
(Relative to ANSI C101-1992 or UL-1459 2nd edition) |
|||
DC to 50Hz |
±2% of reading |
|||
50 Hz to 100 KHz |
±2.5% of reading |
±2% /-3% of reading |
±2% of reading |
|
100 kHz to 1 MHz |
±5% of reading |
|||
Voltmeter range: |
0-300 V (AC or DC) |
|||
Voltmeter accuracy: DC to 1 Hz |
Pointer shall track within 5% of peak |
|||
2Hz to 19Hz (Accuracy not supported) |
|
|||
20 Hz to 1KHz |
±3% F.S. @ 60 Hz (Add ±1% for every additional 100Hz) |
|||
Voltmeter frequency response: |
DC to 1 KHz |
|||
Power requirements: |
Power requirements: (2) 9V (NEDA 1604A) batteries |
|||
Physical: |
7" x 5.25" x 3.125", 2-1/2 lbs (1.4kg), ABS plastic,fusedinput |
|||
Environmental: |
27°C ±2° C, 70% non condensing relative humidity. Outside thisrangederate by 10% per °C |
|||
Maximum operating range: |
0° to 40° C |