DMF-Y-76S,淹沒式脈沖閥,DC24V AC220V AC110V WENA
DYM-89,淹沒式脈沖閥,DC24V AC220V AC110V WENA
DMF-Y-50S,淹沒式脈沖閥,DC24V AC220V AC110V WENA
DMF-Y-62S,淹沒式脈沖閥,DC24V AC220V AC110V WENA
DMF-Y-76S,淹沒式脈沖閥,DC24V AC220V AC110V WENA
DMF-Z-25,直角式脈沖閥,DC24V AC220V AC110V WENA
DMF-Z-40S,直角式脈沖閥,DC24V AC220V AC110V WENA
DMF-Z-50S,直角式脈沖閥,DC24V AC220V AC110V WENA
DMF-Z-62S,直角式脈沖閥,DC24V AC220V AC110V WENA
DMF-Z-76S,直角式脈沖閥,DC24V AC220V AC110V WENA
DMY-II-80,淹沒式脈沖閥,DC24V AC220V AC110V WENA
SP-50,淹沒式脈沖閥,DC24V AC220V AC110V WENA
SP-75,淹沒式脈沖閥,DC24V AC220V AC110V WENA
SQP-75,淹沒式脈沖閥,DC24V AC220V AC110V WENA
CG350F140/100鋼廠油缸
Q23DI-L6,Q23D2I-L6,Q25DI-L6電控換向閥,無錫溫納電控閥
Q25D2I-L6,Q33D2I-L6,Q35D2I-L6電控換向閥,無錫溫納電控閥
Q23DI-10,Q23D2I-10,Q23DI-L8電控換向閥,無錫溫納電控閥
Q23D2I-L8,Q25DI-L8,Q25D2I-L8電控換向閥,無錫溫納電控閥
Q33D2I-L8,Q35D2I-L8,Q23DI-15電控換向閥,無錫溫納電控閥
Q23D2I-15,Q23DI-L10,Q23D2I-L10電控換向閥,無錫溫納電控閥
Q25DI-10,Q25D2I-10,Q25DI-L10電控換向閥,無錫溫納電控閥
Q25D2I-L10,Q33D2I-10,Q22D2I-L10電控換向閥,無錫溫納電控閥
Q35D2I-10,Q35D2I-L10,Q23DI-20電控換向閥,無錫溫納電控閥
Q23D2I-20,Q23DI-L20,Q23D2I-L20電控換向閥,無錫溫納電控閥
Q25DI-20,Q25D2I-20,Q25DI-L20電控換向閥,無錫溫納電控閥
1.電磁脈沖閥輸入電動信號時,膜片在原地抖動,脈沖閥不能停止噴吹。 先導頭動柱在抖動,大膜片阻尼孔磨損變大,卸荷排氣不通。
2.電磁脈沖閥輸入電動信號時,先導頭動柱在原地抖動,脈沖閥不能停止噴吹。
3.電磁脈沖閥輸入電動信號時,觀察導頭不動,其次膜片不動,閥不工作。 線路不通;電壓過低;因現場裝置不當,使先導頭動柱卡死。
4.電信號消逝,先導頭動柱不能復位。 有毛刺或雜質等,使動柱卡死;彈簧疲倦,彈力缺乏;阻尼孔有堵,壓力氣體過不去或氣壓低。
5.電信號消逝,膜片不能復位關閉。 阻尼孔堵死;卸荷孔沒有封鎖。
6.電信號消逝,膜片不能復位關死。 阻尼孔有堵,阻尼作用太大,壓力氣體不能及時到位;靜壓力低;
市場上劣質品種很多,從而導致一些消費者在購買的時候上當受騙“小零件,大作用”,那么脈沖閥膜片就是除塵器系統中的小零件,作用非常大,不可輕視。我們要關注質量,確保給工作帶來影響。
CG350F140/100鋼廠油缸
A:種方式:1hp水冷式冷水機可配8噸鎖模力注塑機溫度控制在5-1度;p水冷式冷水機可配1噸鎖模力注塑機溫度控制在1-15度;p水冷式冷水機可配12噸鎖模力注塑機溫度控制在15-2度;(附風冷式冷水機的匹配為水冷式冷水機的.8倍,即1HP風冷式冷水機可配64噸鎖模力的注塑機溫度控制在5-1度.)B:第二種方式:1HP的水冷式冷水機可配單次注塑量為1QZ的注塑機溫度控制在5-1度.注塑量1QZ=28.5g以上公式為經念總結出來的結果.除運用以上公式外,業務員應考濾實際情況,選擇合適的冷水機.C:冷水機和冷卻水塔的匹配,根據以往的實際經念1HP冷水機需求一臺1.2冷噸的冷卻水塔才能帶走冷水機所產生的熱量。
CJM-5/2-1/2-CH
MSG-24DC
TMF-Z-20
TMF-Z-25
TMF-Z-40S
TMF-Z-50S
TMF-Z-62S
TMF-Z-76S
TMF-Y-20
TMF-Y-25
TMF-Y-40S
TMF-Y-50S
TMF-Y-62S
TMF-Y-76S
TMF-Y-102S
TMF-DY-20
TMF-DY-25
TMF-DY-40S
TMF-DY-50S
TMF-DY-62S