家家通 | 所有行業 | 所有企業 加入家家通,生意很輕松! ·免費注冊 ·登陸家家通 ·設為首頁
關于我們
關于我們
今日加盟
今日加盟
會員中心
會員中心
 
當前位置: 首頁 » 供應產品 » 環保/環保設備 » 污水處理設備 »高壓風機使用場合

高壓風機使用場合

<%=cpname%>
產品價格: 30000/人民幣 
最后更新: 2021-04-13 08:44:40
產品產地: 山東臨沂市
發貨地: 山東臨沂市 (發貨期:當天內發貨)
供應數量: 不限
有效期: 長期有效
最少起訂: 1
瀏覽次數: 260
詢價  試用會員產品
  • 公司基本資料信息
    • 山東臨風科技股份有限公司
    • 宋波先生 副總
    • 會員[試用會員產品]
    • 郵件13853987066@163.com
    • 手機13853987066
    • 電話
    • 傳真
    • 地址臨沂經濟技術開發區杭州路25號
    • 進入商鋪
     
    產品詳細說明

    Purpose?and characteristics?of the fan

    ???Model?9-19?centrifugal fan is generally used for forging furnace and high pressure forced ventilation, widely used for materiel delivery and suitable to delivery air and gas of non-corrosion, non self-burn and free of viscous material. The temperature of the delivered medium shall normally not exceed 250℃?(not exceed?300℃?maximum), the dust contained in the medium and hard-fine particle shall not be bigger than 150mg/m3. This series of fans in addition to the above characteristics, but also has high efficiency, low noise, large flow adjustment range, flat performance curve and so on. Fan three high degree of versatility, good versatility, wide range of application.

    Type of fan

    ???1. The fan is made as a single suction and its driving is A type. There are more than 20?types of fan numbers which are 33.15、4、4.5、5、5.6、6.37.1、8、9、10、11.2、1212.514、16、18、and 20.

    2. The fan can be made of 2 types of rotation i.e, right and left. Viewing from one end of the motor, it is called as clock-wise fan if the impeller rotates clock-wise, shown as “right”, On the contrary, it is called as counter-clock-wise fan if the impeller rotates counter-clock-wise, shown as “left”.

    3. The outlet position of the fan can be expressed from the outlet?angle of the casing. It can be made 7?kinds of angles which are 0°, 45°,90°, 135°,180°,225°,?270°,from both “Right” and “left”.

    4. There are 4 driving modes: A,B, C, D:

    AShaft disc of fan is installed on motor shaft by keyway, i.e. motor directly connecting; ??

    B—Cantilever bearing unit, belt driving, pulley is in the middle of two bearings;

    CCantilever bearing unit, belt driving, but the pulley is outside the bearing;

    DCantilever bearing unit, coupling directly driving.

    Structure of the fan

    №3-7.1?fan mainly consists of impeller, casing and inlet. №7.1-?above?fan mainly consists of impeller, casing inlet?and?Driving?unit.

    Casing:?to be welded into a volute with normal steel plate.

    Impeller: The fan has 12?forward-curved blades. The maximum circumference speed of impeller diffuser shall not exceed 140m/s. The impeller, after being shaped, shall be balanced statically and dynamicaly and thus it guarantees a smooth operation.

    Inlet: to be integrated into a convergent streamlined structure and bolted on the front cover.

    Driving unit—it consists of shaft, bearing box, rolling bearing, belt pulley or coupling.

    See the attached drawing for installation and overall dimension.

    Performance and selection of the fan

    Performance of the fan:The performance of the fan is expressed by the parameters of fan flow, full pressure, spindle speed, shaft power and so on.?Performance curve and the performance of the performance given in the table. Blower performance:20 degrees Celsius, atmospheric pressure is 101325 Pascal,Gas density is 1.2Kg/m3,calculation and calculation of air medium. (Other designs are similar to the use of parameters.)

    The performance of both the selection curve and the performance table refers to the performance of adjusting the blade to a full 0 degree centigrade. When ordering the performance table shall prevail. Fan performance test total pressure value of 5% of the total pressure deviation is less than design value.

    Such as fan using condition does not accord with the above, the performance shall be carried out according to the related formula conversion.

    When excessive or insufficient flow of processing. When use, often occur the phenomenon of excessive or insufficient flow, produce a lot of reasons for this phenomenon, if it is in use process flow occurs when small phenomenon, is mainly due to the resistance of pipe network. If it is in use process, after a long time to reduce gradually, mainly due to network congestion.

    After the fan is a new installation, a formal operation occurs when the flow phenomenon of excessive or insufficient reason mainly has the following points:

    1.?The actual value and calculating value difference is too large in the resistance of pipelines.

    By the general network characteristic equation: P = Kq2, type of K - drag coefficient.

    If the actual value K is less than the calculated value K, increases the flow, if the actual value?K is greater than the calculated value?K,?the flow decreases.

    2.?when the choice is not the fan itself fully considering the influence of the pressure deviation of δP,?when?the?fan actual total pressure for positive deviation, then the flow; Negative deviation, the flow rate decreases.

    Began formal operation after fan is a new installation, or in use process flow is too big or too small, one of the following methods can be used to eliminate it.

    Make use of the fan speed adjusting flow increase or decrease.

    Using the new high or low pressure switch to increase or decrease in flow rate of fan.

    Change the pipeline resistance coefficient K to change traffic.

    At this time to try to change the network reduce drag coefficient to increase traffic, also can increase the fan rotation speed and changing the high pressure fan, but speed shall not be greater than the maximum speed performance table.

    The basis and the shape of the fan

    9-19 type fan shape and see the appended drawings

    Installation and operation of the fan

    ?Before installation: Check all components of the fan to see weather any thing is missed; weather the impeller rotates in the same direction as the casing; weather all components are connected tightly and weather the impeller rotates freely.

    During installation: Pay attention to check the casing and any tools or goods should not be dropped and remained inside the casing. The connecting face between the support of the fan and the foundation or between pads and foundation should be tight. Adjusting should be made to joint the fan with foundation surface and to connect the fan with suction, discharge duct naturally. Forced assembling, especially, applying weight of pipes on any components of the fan isimpermissible. Also, attention shall be paid to the horizontality of the fan.

    Requirement of installation:

    1.?Install the fan according to the position and sizes shown on the drawing. To insure high efficiency, radial and axial clearances between inlet and impeller must be guaranteed.

    2.?After installation, turn, with a little force, the driving rotor to see if it is over tight or touched with stationary components.

    3. Commission Can only be carried out after the unit is through the final inspection.

    4. In order to prevent the motor being burnt out due to overloading, the fan can only be started up and tested without loading. If the case is ok, increase the load step by step until the rated operating condition is reached. Control the current strictly during operation to prevent it exceeding the rated value.

    Operation?of?the?fan:

    ??Before starting-up, the following preparations shall be made:

    1) Close the valve of suction pipe and open a little the valve on discharge pipe.

    2) Check the rotating and non –rotating parts to prevent colliding and friction.

    3) After the fan is started-up and the normal speed is reached, check the bearing temperature is normal or not during the operation. If there is no special requirement for bearing temperature, the temperature rise of the bearing shall not exceed 40℃?of surrounding temperature. The value of even root vibration speed of the bearing shall comply with the following rules: rigid support(support is fixed on the foundation) Vrms≤4.6mm/s; flexible support(be set onfoundation or floor through absorber) Vrms≤7.1mm/s. In case that severe vibration, colliding, quick rise of bearing temperature and other abnormal phenomena are found, stop the fan immediately.

    Maintenance of the fan

    1. Don’t allow fan with trouble running.

    2. Don’t freely change the maintenance person, specific person operating and repair the fan is preferred.

    3. Regularly remove dust, contamination and the foreign materials and prevent rust .

    4. Maintenance can be carried out during shut down of fan to assure operators safety.

    5. When the fan is repaired, the motor switch must be monitored or locked.

    6. Inspect the thermometer and oil indicator regularly.

    7. During the star-up, shut-down or operation of the fan, if some abnormal thing happens, inspections shall be carried out immediately; if it is small failure, the reason shall be checked out and eliminated, if it is a big failure, the fan shall be stopped and inspection and maintenance shall be made immediately.

    8.?Except replacing the lubricant after overall, replace the lubricating oil periodically.


    在線詢盤/留言 請仔細填寫準確及時的聯系到你!
    您的姓名: * 預計需求數量: *    
    聯系手機: * 移動電話或傳真:
    電子郵件: * 所在單位:
    咨詢內容:
    *
     
    更多..本企業其它產品

    機電之家網 - 機電行業權威網絡宣傳媒體

    Copyright 2025 jdzj.com All Rights Reserved??技術支持:機電之家 服務熱線:0571-87774297

    網站經營許可證:浙B2-20080178-4

    主站蜘蛛池模板: 熟妇人妻久久中文字幕| 青青青青久在线观看视频| 奷小罗莉在线观看国产| 久久久久亚洲AV无码专区网站| 欧美xxxx狂喷水| 亚洲欧美日韩国产vr在线观| 男人桶女人机完整视频| 午夜无码A级毛片免费视频 | 日韩AV无码一区二区三区不卡毛片 | 欧美日韩免费在线视频| 亚洲香蕉免费有线视频| 精品久久久无码中文字幕| 啊灬啊灬啊灬快好深视频在线| 观看国产色欲色欲色欲www| 国产成人无码精品久久二区三区| yy6080理aa级伦大片一级毛片| 国内国外精品影片无人区| h在线看免费视频网站男男| 性一交一乱一伦一| 中文字幕视频在线| 日本大片免a费观看视频| 久久精品青青大伊人av| 樱花草在线社区www| 亚洲人成在久久综合网站| 欧美日韩精品一区二区三区高清视频 | 免费永久在线观看黄网站| 约会只c不y什么意思| 国产91精品系列在线观看| 色综合天天综合| 国产亚洲精品aa片在线观看网站| 韩国无码av片| 国产大片内射1区2区| 黑人巨大sv张丽在线播放| 国产成人精品免费久久久久 | 无码av无码天堂资源网| 久久久久久久久久久久福利| 日本护士xxxx黑人巨大| 久久亚洲色一区二区三区| 日韩免费毛片视频| 久久精品人人做人人爽电影蜜月| 日韩精品一卡2卡3卡4卡三卡 |