雙排顯示PV、SP等數據
12種熱電偶信號、3種熱電阻信號、5種線形信號輸入
繼電器輸出、電壓、電流信號輸出
帶手/自動模式,切換便利
多種輔助輸出功能
多種控制算法輸出:ON/OFF、PID、雙重(冷熱區)輸出、馬達閥門控制,單相/三相可控硅控制
三路(可選)報警輸出,17種報警類型
8段設定點程序
滿量程0.5%精度,EEROM非易失性內存,確保數據在掉電情況下不會丟失
85-256Vac/50(60)HZ供電工作
PXR4系列選型說明
PXR9 |
PXR5 |
PXR7 |
PXR4 |
PXR3 |
面板(96x96mm) |
(48x96mm) |
(72x72mm) |
(48x48mm) |
(24x48mm) | 開孔(92*92mm) (45*92mm) (68*68mm) (45*45mm) (22*45mm)
|
數字位 |
規格 |
代號 |
|
4 |
5 |
6 |
7 |
8 |
- |
9 |
10 |
11 |
12 |
13 |
4 |
面板尺寸H*W |
|
|
|
|
|
|
|
|
|
|
|
48*48 |
4 |
|
|
|
|
|
|
|
|
|
|
5 |
輸入信號 |
|
|
|
|
|
|
|
|
|
|
|
熱電偶(℃) |
|
T |
|
|
|
|
|
|
|
|
|
熱電偶(F) |
|
R |
|
|
|
|
|
|
|
|
|
RTD/PT100(℃) |
|
N |
|
|
|
|
|
|
|
|
|
RTD/PT100(F) |
|
S |
|
|
|
|
|
|
|
|
|
1~5V DC |
|
A |
|
|
|
|
|
|
|
|
|
4~20mA DC |
|
B |
|
|
|
|
|
|
|
|
|
6 |
控制輸出1 |
|
|
|
|
|
|
|
|
|
|
|
繼電器接點輸出 |
|
|
A |
|
|
|
|
|
|
|
|
SSR/SSC驅動輸出 |
|
|
C |
|
|
|
|
|
|
|
|
4~20mA DC輸出 |
|
|
E |
|
|
|
|
|
|
|
|
7 |
控制輸出2 |
|
|
|
|
|
|
|
|
|
|
|
無 |
|
|
|
Y |
|
|
|
|
|
|
|
繼電器接點輸出 注1 |
|
|
|
A |
|
|
|
|
|
|
|
SSR/SSC驅動輸出 注1 |
|
|
|
C |
|
|
|
|
|
|
|
4~20mA DC輸出 注1 |
|
|
|
E |
|
|
|
|
|
|
|
再傳輸出(4-20Ma DC) |
|
|
|
R |
|
|
|
|
|
|
|
8 |
版本號 |
|
|
|
|
1 |
- |
|
|
|
|
|
9 |
附加功能1 |
|
|
|
|
|
|
|
|
|
|
|
無報警 |
|
|
|
|
|
|
0 |
|
|
|
|
1個報警 |
|
|
|
|
|
|
1 |
|
|
|
|
加熱器斷路報警 注3 |
|
|
|
|
|
|
2 |
|
|
|
|
1個報警+加熱器斷路報警 注3 |
|
|
|
|
|
|
3 |
|
|
|
|
8段斜坡/保溫程序 |
|
|
|
|
|
|
4 |
|
|
|
|
1個報警+8段斜坡/保溫程序 |
|
|
|
|
|
|
5 |
|
|
|
|
加熱器斷路報警+8段斜坡/保溫程序注3 |
|
|
|
|
|
|
6 |
|
|
|
|
1個報警+加熱器斷路報警+8段斜坡/保溫程序 注3 |
|
|
|
|
|
|
7 |
|
|
|
|
兩個報警 |
|
|
|
|
|
|
F |
|
|
|
|
兩個報警+8段斜坡/保溫 |
|
|
|
|
|
|
G |
|
|
|
|
2個報警+加熱器斷路報警+8段斜坡/保溫程序 注3 |
|
|
|
|
|
|
H |
|
|
|
|
3個報警 |
|
|
|
|
|
|
M |
|
|
|
|
遙控設定 注3 |
|
|
|
|
|
|
D |
|
|
|
|
遙控設定+2個報警 注3 |
|
|
|
|
|
|
P |
|
|
|
|
10 |
操作說明書 電源電壓 |
|
|
|
|
|
|
|
|
|
|
|
無100-240V |
|
|
|
|
|
|
|
N |
|
|
|
日文100-240V |
|
|
|
|
|
|
|
Y |
|
|
|
英文100-240V |
|
|
|
|
|
|
|
V |
|
|
|
無24VAC/24VDC |
|
|
|
|
|
|
|
C |
|
|
|
日文24VAC/24VDC |
|
|
|
|
|
|
|
A |
|
|
|
英文24VAC/24VDC |
|
|
|
|
|
|
|
B |
|
|
|
11
12
13 |
附加功能2 |
|
|
|
|
|
|
|
|
|
|
|
無 |
|
|
|
|
|
|
|
|
0 |
0 |
0 |
RS485 (MODBUS)通訊 |
|
|
|
|
|
|
|
|
M |
0 |
0 |
RS485 (Z-ASC11)通訊 |
|
|
|
|
|
|
|
|
N |
0 |
0 |
1點數字輸入 |
|
|
|
|
|
|
|
|
Q |
0 |
0 |
2點數字輸入 注4 |
|
|
|
|
|
|
|
|
T |
0 |
0 |
RS485(MODBUS)通訊+1點數字輸入 |
|
|
|
|
|
|
|
|
V |
0 |
0 |
RS485(Z-ASC11)通訊+1點數字輸入 |
|
|
|
|
|
|
|
|
W |
0 |
0 |
注1:輸出4-20mA 不能與加熱器斷路報警一起選.(即選項9中的2、3、6、7) |
注2:不能和1個報警+加熱器斷路報警或兩個報警一起選。(即選項9中的3、7、F、G、H) |
注3:不能與RS485+1點數字輸入一起選。(即選項11、12、13中的V00) |
注4:若選擇2點數字輸入,輸出2或加熱器斷路報警不能選。 |